Spectroline Quadran QDR-365A Dual Intensity Multi-LED (QDR-365BLA)

    Spectroline Quadran QDR-365A Dual Intensity Multi-LED
     

     

    DISCONTINUED

    Click Here to view the product that replaced this product.

    This product has been discontinued.
    Click Here to view the replacement product.


    • Product Codes:
      QDR-365BLA_QDR-365BL
    • Original Code:
      QDR-365BL
    • Tech Support Available
    • Product Weight: 4.00

    HAVE A QUESTION?
       Hours:   8:00 am to 4:30 pm CST

    Description

    QUADRAN™ 365 Series NDT lamps feature four ultra-hi-flux UV-A LEDs plus a convenient white light LED to quickly switch between fluorescent inspection and flaw location. A unique dual-intensity feature provides both high and standard UV-A and white light output for added versatility.

    The lamps’ broad-beam configuration produces an extremely wide coverage area, making them ideal for both handheld and in-line applications. 

    When the QDR-365 is in high intensity mode, the lamp provides a nominal steady-state UV-A intensity of 8,000 μW/cmat 15 inches (38 cm). 


    When switched to the standard intensity mode, the QDR-365 provides a nominal steady-state UV-A intensity of 4,500 μW/cm2 at 15 inches (38 cm).
     
    In addition, the lamp has a high/low switch to control the white light LED output.
    UV-A Beam Profile


     
    As the wavelength of the QUADRAN™ 365 moves into the visible light range, the black light filters significantly reduce the output of the lamp at 400 nm.
    Typical wavelength output profile of QUADRAN™ 365 Series lamps with and without black light filter.


     

     

    Features

    Quadran 365 Dual Intensity Multi-LED Broad-Beam Lamp Features:
     
    • Dual-intensity capability: High setting produces a nominal steady-state UV-A intensity as high as 8,000 μW/cm2; standard setting produces a nominal steady-state intensity of 4,500 μW/cm2, both at 15 inches (38 cm)
    • Extremely large coverage area of up to 6 inches (15 cm), with a minimum UV-A intensity of 2,000 μW/cm2
    • Low visible light emission — less than 2 foot-candles (22 lux)
    • Conveniently located rocker switches for quick and easy control of light sources
    • Built-in fan keeps LEDs cool to maintain optimum light output during extended use
    • Rubber bumper with Borofloat® glass lens protects LEDs from damage
    • Rugged, modular construction allows for easy field serviceability
    • Lamp handle pin receptacle allows for easy attachment of various Spectroline® mounting accessories for in-line inspection applications (accessories sold separately)
    • UV-absorbing spectacles and soft carrying case included

    Package Includes

    • Quadran 365 Dual Intensity Multi-LED Broad-Beam Lamp
    • FP-550 Borofloat Filter Protector
    • Faceplate
    • Heavy Duty 8 Foot Cord
    • UVS-30 UV Absorbing Spectacles
    • Soft Carrying Case

    RECENTLY VIEWED PRODUCTS

    carousel button
    • Chemetall Ardrox 9D1B Developer Powder
    • Berg 10mm Carbide Brinell Ball (ea)
    • Labino BB Helios DUO Midlight
    • Chemetall Ardrox 9812 Post Emulsifiable Fluorescent Penetrant
    • GE Inspection Technologies Surface Probe Kit Eddy Current Surface Probe Kit
    • Buehler Cut-off Wheels, 9 x 0.063 x 1 1/4
    • Sonotech Sonoglide UP GR20
    • MagnaFlux Sono 1100 High-Temperature Ultrasonic Couplant
    • MagnaFlux 20 Gauss Field Meter, Calibrated
    • MagnaFlux P-Series Remote
    • Sonotech Sonotrace GR40
    • FW Bell SAD58-1902 2"" Axial Probe
    • Sensit P100 Personal Gas Leak Monitor
    • Mitutoyo LCD protective sheet (10 sheets per set) (SJ301)
    • MagnaFlux Zyglo ZL-56 Level 4 Water Washable Fluorescent Penetrant
    • FlawTech RA-266 Advanced Specimen
    • Circle Systems CircleSafe 850A Water Based Dual Response, Case Of 12x19oz Cans
    • GE Stresstel General Purpose & Through Coating Probe, 3/8" dia., 5MHz, Bell Housing Case, MD
    • Waygate Technologies DA301 Standard Probe, 5 MHz, 0.48" Contact Dia.(Requires KBA533 Cable)
    • MagnaFlux Steady Rest, Rail-mounted
    • Chemetall Ardrox 8505 Fluorescent Magnetic Dry Powder
    • Berg BHN 1000 kg 110 range
    • Wilson 2000 Series Load Cell Rockwell Tester
    • PH Tool Navy Eddy Current Standard, 6AL-4V Titanium
    • Machida FBA-8-100 8mm Diameter Fiberscope
    • Foerster SIGMATEST 2.069 Operating Instructions CD
    • Hawkeye Gradient Lens Slim 7" 4.20mm Diameter Borescope HS07-AF-KIT
    • Waygate Stresstel High Resolution Transducer, 1/4" dia., 5MHz, Knurled Case, 4ft. Top Potted Cable
    • Waygate Krautkramer Rowa Series Bar/Tube/Pipe Ultrasonic Test Machine
    • Wilson Flat Anvil, 190 mm
    • GE Dyna G
    • Berg Orange Quality RG174 Ultrasonic Flaw Cable, Lemo 01 to Microdot, 3 ft
    • Probe Rotating, Rigid, Dia = 11.51mm (29/64”), wl = 35mm
    • GE Inspection Technologies Eddy Current Probe Cable
    • FlawTech L-R 90 Degree Elbow to Pipe
    • Waygate Technologies Retrieval Tool Kit for 8.4 mm probe, 7.8 m working length
    • Mitutoyo Gear tooth surface stylus 10μm
    • Jireh Center Base
    • Spectroline Blue Lamp Head for OPK-300N Kit
    • Circle Systems Reference Block Type 1 MTU-3
    • Mitutoyo Standard 10μm stylus
    • Waygate Technologies 45 Degree Wedge Angle, 0.250"
    • Waygate Stresstel High Temperature Probe, 1/4" dia., 5MHz, Insulated Case, 4ft. Potted Cable
    • PH Tool Navy Eddy Current Standard, 7075-T651/T73 Aluminum
    • Waygate Krautkramer Squirter / Immersion Tank System
    • Mitutoyo 0.6-1.2" Measuring Range / 0.5-2.5N Force
    • Labino MidBeam Variable Gooseneck Arm
    • Waygate Stresstel General Purpose Probe, 1/4" dia., 5MHz, Knurled Case, 4ft. Potted Cable
    • Flawtech P310 – Gear Rack – Carbon Steel
    • Sensit HXG-3P Combustible Gas Detector with Pump
    • Wilson 400 Series Knoop/ Vickers Tester
    carousel Button