    Description



    The Dakota Ultrasonics CMXDLP+ is the premium model in the CMX Series of Gauges. It efficiently measures both coating and wall thickness from a single side. In Pulse-Echo mode, it automatically eliminates coating thickness, aiding in pinpointing corrosion and pitting without removing the coating.

    The A-Scan Display Mode shows waveform echoes graphically, facilitating optimal gauge settings adjustment. The new E-EV Operating Mode ("Echo-Echo-Verify") ensures measurement accuracy by verifying with subsequent echoes.

    The oversized backlit LCD displays critical settings, including Velocity, Operating Mode, Alarms, and Scan Mode. The backlight can be set to ON, OFF, or AUTO.

    Five user-selected operating modes are available:

    Coating On: Measures wall and coating thickness separately using Pulse-Echo.

    Coating Off: Measures wall thickness only using Pulse-Echo.

    Temperature Compensated: Adjusts calibration for material temperature changes while measuring wall thickness using Pulse-Echo.

    Thru-Coat: Measures wall thickness only using Echo-Echo, excluding coating.

    Coating Only Mode (CT): Measures coating thickness in the range of 0.0005 to 0.100 inches (0.013 to 2.540 mm). Range may vary slightly based on the coating.




    Features

    • Built-in memory with RS-232 output for transferring data to a Printer or PC
    • Includes Datacomm Data Transfer & Analysis Software and RS-232 Cable, FREE
    • Data Files can be user-set for a "grid type" structure where data is formatted in Rows & Columns or a "sequential" file where all data appears in a single column
    • Each "grid type" File can be set for up to 999 rows by 52 columns
    • Each "sequential" File can be set for up to 512 rows by 1 column
    • Each File can be set for "data only" or as "data plus B-scan Graphic". Memory Capacity is over 225,000 data values or over
    • 16,000 data values with B-scan
    • Wide variety of dual-element probes can be used for nearly any application
    • Adjustable Gain in 5 steps (VLow, Low, Med, Hi & VHi) in 2db increments providing a 8 db gain adjust range (42–50 db)
    • 64 custom setups can be stored and retrieved for convenient use and labeled for easy identification

     

    Specs

    Range in Steel: Pulse-Echo Mode: Pit and Flaw detection measures from 0.025 - 9.999inches (0.63 to 254 millimeters)

    Echo-Echo Mode: Thru Paint & coatings measures from 0.100 - 4.000 inches (2.54 to 102 mm). Range will vary depending on the thick
    Range in Coating Only Mode 0.0005" - 0.1000" / Resolution: 0.0001"
    (0.013 - 2.540 mm / Resolution: 0.001 mm)
    Max Coating 0.100"
    Resolution: .001 inches (0.01mm)
    Velocity Range: .0492 to .3936 in./ms
    1250 to 9999 meters/sec
    Units: Inch or mm
    Measurement Modes: - Pulse-Echo (corrosion mode)
    - Pulse-Echo Coating (Corrosion w/o coating)
    - Echo-Echo (thru-paint)
    - Temp Comp (auto adjust for material temp)
    - Coating Only (Ultrasonic Coating Gauge)
    Transducer Types: Dual Element (1 to 10 MHz).
    Output RS-232 for upload/download of setups
    Memory capacity: TI-CMXDLP: over 200,000 measurements
    Power Source: Three 1.5V alkaline or 1.2V NiCad AA cells
    Battery Life: Typically operates for 150 hours on alkaline and 100 hours on NiCad
    Auto Power off: After 5 minutes of non-use
    Display: 1/8 in. VGA grayscale display 62 x 45.7mm
    Keyboard: Membrane switch with twelve tactile keys
    Case: Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed).
    Temp. Limits Ambient: -20 to 120° F (-30 to 50° C)
    Material: -0 to 200° F (-20 to 100° C
    Special high temperature probes are optionally available.
    Weight, net: 383 grams
    Dimensions: 63.5 W x 165 H x 31.5 D mm
    Warranty: 2 year limited
    Certification: CE Approved, Factory calibration traceable to national standards

    Additional Info

    Package Includes

    • CMXDL-PLUS Corrosion Thickness Gauge and Probe
    • Bottle of Coupling Fluid
    • 2 AA Batteries
    • NIST-Traceable Calibration Certificate
    • Operating Manual
    •  RS-232 cable
    • Carrying Case

    RECENTLY VIEWED PRODUCTS

    carousel button
    • Berg RG-174 Ultrasonic Probe Cable BNC to MD 50' Cable
    • Wohler 1" Camera Head V2
    • Sensor Networks Phased Array Linear Membrane Transducers
    • Wilson 1/2" Diameter Carbide Ball, each
    • GE TM1D Precision Ultrasonic Thickness Gauge
    • Sensor Networks Phased Array Small Footprint Transducers
    • Wilson Single Bar Jominy Fixture
    • Gould-Bass CR2000 Handheld Mercury Vapor UV Blacklight
    • FlawTech MA-234 Advanced Specimen
    • Wilson C Brale, Gear Roots & Groves NIST
    • Wilson Single Bar Jominy Fixture
    • Spectroline 1 - 254nm 15 Watt Tube and Filter Assembly (120V/60Hz)
    • Mitutoyo USB Input Tool Interface Box
    • Foerster Titan 14mm Diameter Probe with Handgrip SigmaTest 2.070
    • Labino Orion L3105 Slave UV Overhead Light 4500 μw/cm2
    • Waygate Krautkramer Dyna-D50 Impact Device Cable
    • Synergys VShooter Easy Vibration Analyzer with Embedded Cam4801.00era
    • GE Tip Optic Case
    • Berg "N" Scale Tapered Diamond w/ certificate - Class B
    • FlawTech VA-285 Advanced Specimen
    • Wilson Large Capacity Clamp and Leveling Device
    • Wilson Micro Knoop Indenter
    • Wilson Test Blocking Gridding
    • Spectroline ML-3500D Diffused
    • Berg CX230 QQI Test Shims
    • Waygate Technologies LCD Monitor
    • GE XLG3 Air Filter
    • Parker Switch, AC/DC DA400, 115VAC
    • Labino MidBeam 2.0 Zeus Handheld LED UV & White Light
    • Tramex Water Damage Restoration Inspection Kit
    • SPI RAZIR Long Range Telephoto Zoom Germanium Lens
    • Danatronics Gooseneck Adapter
    • MagnaFlux P-1500 Portable Power Pack
    • Sonotech Glycerine 12 oz Bottle
    • DeFelsko PosiTest HHD Replacement Battery
    • Danatronics Suction Cup Stand
    • Wilson C Ring Grip Brale NIST
    • Berg HRA Scale 86-90 Calibrated
    • FlawTech ET 101B Advanced Specimen
    • Wilson 2001M - MicroRockwell Production Microindentation Hardness Testing System
    • Zetec ZPA-ACC-W-AL-55LW-IH-FL
    • FlawTech Standard Magnetic Particle-Liquid Penetrant Kit
    • GE Inspection Technologies (Krautkramer) USN60L Ultrasonic Flaw Detector
    • Mitutoyo 1PI  BALL CONTACT POINT(ECCENTRICIT
    • Echo Spot Weld Ambient temperature UT couplant for spot weld inspections
    • Ofil Railway Corona Inspection System with DayCor
    • Wilson 1/2" Carbide Ball Indenter with 1 additional carbide ball
    • MagnaFlux Daraclean 257 Alkaline Aerospace Cleaner
    • MagnaFlux Split coil 24" diameter 4/0 cable, Eitherend connectors
    • Wilson C Long Body Brale NIST
    • Circle Systems MI-GLOW 778 Liquid Concentrate 4x1 Quart Case
    • Spectroline UVA Fan Cooled Lamp 100 Watt Spot 8ft and 20ft Cords
    • Berg C, A, D Scale Diamond with certificate - Class B
    • Berg UV Torch
    • Technisonic 5MHz, High Res, ¼” diameter  Transducer
    • Magnaflux ZL-150 Level 2 Water Washable Fluorescent Penetrant
    • Wilson C Short Nib Brale
    • Bruker TRACER 5 PROLENE transparent protective window, pkg of 5
    • GE XLG3 Shoulder Strap
    • Wilson Yamamoto 32 HRA with certificate
    • Olympus C080ZI-012-090-60 8mm Diameter Borescope
    • Mitutoyo Digital Micrometer
    • Mitutoyo Deep grove 10 stylus 2μm
    carousel Button