    The USIP 20 systems flaw detector - High performance and multichannel

    Four flaw gates, each with two thresholds, give complete versatility of test configuration. Floppy and hard disk recording media allow for ease of setup storage and recall, and for transfer of parameters from instrument to instrument. 

    Control menus are displayed on a large, bright LCD and adjustments easily made through both dedicated and variable function controls. "Ease of use" has been our key phrase in the development of the USIP 20.Each control menu is displayed using a devoted function key, so that no standard operating menu is further than a single button push away.

    · Easy to use
    · High performance
    · Up to four flaw gates plus interface gate
    · Gate start within 50 nanoseconds of interface
    · Menu configurable outputs and sorting logic
    · Internal PC allows flexible communication
    · On-board storage of setups on standard DOS disk hardware
    · 1 - 256 channel configuration

    Base Instrument Package:

    · Interface Gate Synchronization
    · 60 point DAC
    · 2 Flaw Gates (2 thresholds/gate)
    · 4 TTL Outputs
    · 2 Analog Amplitude Outputs
    · Output Connector Cable
    · Internal Hard Disk Drive
    · Internal Floppy Disk Drive (1.44 MB)
    · Power Cable
    · Certificate of Conformity
    · Operating Manual

    Optional Accessories:

    · 2 Additional Flaw Gates
    · Remote High Frequency Pulser Pre-Amp (HFTR)
    · 16 Bit Computer I/O (USIP20 Side Only)
    · Extended Dynamic Range (extends range to 60 dB and DAC to 80 dB) Includes Back Echo Attenuation (022-505-862)
    · Back Echo Attenuation
    · Extender Module

    Specifications:

    Standard Pulser
    Transmitter Voltage, 40/400V
    Pulse Rise Time, 10 ns
    Maximum PRF 1 Channel, 10 kHz
    HFTR Pulser
    Transmitter Voltage, 220V
    Pulse Rise Time, 3 ns
    Amplifier
    Main Amplifier, 0.1 to 100 MHz (3 dB)
    Standard Pre-Amplifier, 0.1 to 30 MHz (-3 dB)
    HFTR Pre-Amplifier, 0.1 to 120 MHz (-3dB)
    Settings, BB, 0.5 to 25, 1, 2.5, 5, 10, 15, 25 MHz
    Attenuator, 0 to 120 dB 0.1 dB steps
    Rectification, Pos., Neg., Full, RF Filter, 0-16 points
    Interface Gate
    Start Position, 0.005" to 80" (steel), (0.10 mm to 2000 mm )
    Start Time, 50 ns
    Width, 0.002" to 80" (steel), (0.06 mm to 2000 mm)
    Resolution, 0.005" (steel), (0.10 mm)
    Trigger Threshold, 5% steps in immersion mode water
    Distance to interface is displayed on LCD menu
    DAC
    Number of points, up to 60
    Dynamic Range, 45 dB
    Resolution: Gain, 0.10 dB ; Time, 50 ns, 0.005" in steel (0.10 mm)
    Max. Slope (at 10 MHz), 12 dB/0.10" (2.5 mm)
    Material Attenuation, correlation feature
    Flaw Gates
    Number of Gates, 2 or 4 (option)
    Start, 0.005" to 80" (0.127mm to 2032mm) (steel)
    Width, 0.002" to 80" (0.051mm to 2032mm) (steel)
    Resolution, 0.005" (0.10 mm)
    Thresholds, 2 per gate 10% to 100%
    Threshold Alarm Display, 5 LED's
    Threshold Resolution, 0.5% steps
    Interference Suppression, 1 - 16 counts (per threshold)
    Display, Bars or Steps
    Start Modes, Initial Pulse, Interface, Artificial
    Slave Gate(s)
    Display
    CRT, 4" x 4 3/4" (100 mm x 120 mm)
    Test Range, 0.1" to 312" (2.5 mm to 6.8 meters) typical in steel
    Number of A-scans, 1 or 2
    Sweep Start Modes, Initial Pulse; Interface Echo; Artificial; Display delay;
    Interface Echo + Delay
    General
    Dimensions (H x W x D), 8.7" x 17.64" x 18.9" (221 mm x 448 mm x 480 mm)
    Weight, 50.7 lbs. (23 kg)
    Storage Temperature: -4 to 140oF (-20 to +60oC)
    Operation Temp. : 41 to 104oF (+5 to +40oC)
    Power Supply, 110 or 220 V +/- 10%