The USIP 20 systems flaw detector - High performance and multichannel
Four flaw gates, each with two thresholds, give complete versatility of test configuration. Floppy and hard disk recording media allow for ease of setup storage and recall, and for transfer of parameters from instrument to instrument.
Control menus are displayed on a large, bright LCD and adjustments easily made through both dedicated and variable function controls. "Ease of use" has been our key phrase in the development of the USIP 20.Each control menu is displayed using a devoted function key, so that no standard operating menu is further than a single button push away.
· Easy to use
· High performance
· Up to four flaw gates plus interface gate
· Gate start within 50 nanoseconds of interface
· Menu configurable outputs and sorting logic
· Internal PC allows flexible communication
· On-board storage of setups on standard DOS disk hardware
· 1 - 256 channel configuration
Base Instrument Package:
· Interface Gate Synchronization
· 60 point DAC
· 2 Flaw Gates (2 thresholds/gate)
· 4 TTL Outputs
· 2 Analog Amplitude Outputs
· Output Connector Cable
· Internal Hard Disk Drive
· Internal Floppy Disk Drive (1.44 MB)
· Power Cable
· Certificate of Conformity
· Operating Manual
Optional Accessories:
· 2 Additional Flaw Gates
· Remote High Frequency Pulser Pre-Amp (HFTR)
· 16 Bit Computer I/O (USIP20 Side Only)
· Extended Dynamic Range (extends range to 60 dB and DAC to 80 dB) Includes Back Echo Attenuation (022-505-862)
· Back Echo Attenuation
· Extender Module
Specifications:
Standard Pulser
Transmitter Voltage, 40/400V
Pulse Rise Time, 10 ns
Maximum PRF 1 Channel, 10 kHz
HFTR Pulser
Transmitter Voltage, 220V
Pulse Rise Time, 3 ns
Amplifier
Main Amplifier, 0.1 to 100 MHz (3 dB)
Standard Pre-Amplifier, 0.1 to 30 MHz (-3 dB)
HFTR Pre-Amplifier, 0.1 to 120 MHz (-3dB)
Settings, BB, 0.5 to 25, 1, 2.5, 5, 10, 15, 25 MHz
Attenuator, 0 to 120 dB 0.1 dB steps
Rectification, Pos., Neg., Full, RF Filter, 0-16 points
Interface Gate
Start Position, 0.005" to 80" (steel), (0.10 mm to 2000 mm )
Start Time, 50 ns
Width, 0.002" to 80" (steel), (0.06 mm to 2000 mm)
Resolution, 0.005" (steel), (0.10 mm)
Trigger Threshold, 5% steps in immersion mode water
Distance to interface is displayed on LCD menu
DAC
Number of points, up to 60
Dynamic Range, 45 dB
Resolution: Gain, 0.10 dB ; Time, 50 ns, 0.005" in steel (0.10 mm)
Max. Slope (at 10 MHz), 12 dB/0.10" (2.5 mm)
Material Attenuation, correlation feature
Flaw Gates
Number of Gates, 2 or 4 (option)
Start, 0.005" to 80" (0.127mm to 2032mm) (steel)
Width, 0.002" to 80" (0.051mm to 2032mm) (steel)
Resolution, 0.005" (0.10 mm)
Thresholds, 2 per gate 10% to 100%
Threshold Alarm Display, 5 LED's
Threshold Resolution, 0.5% steps
Interference Suppression, 1 - 16 counts (per threshold)
Display, Bars or Steps
Start Modes, Initial Pulse, Interface, Artificial
Slave Gate(s)
Display
CRT, 4" x 4 3/4" (100 mm x 120 mm)
Test Range, 0.1" to 312" (2.5 mm to 6.8 meters) typical in steel
Number of A-scans, 1 or 2
Sweep Start Modes, Initial Pulse; Interface Echo; Artificial; Display delay;
Interface Echo + Delay
General
Dimensions (H x W x D), 8.7" x 17.64" x 18.9" (221 mm x 448 mm x 480 mm)
Weight, 50.7 lbs. (23 kg)
Storage Temperature: -4 to 140oF (-20 to +60oC)
Operation Temp. : 41 to 104oF (+5 to +40oC)
Power Supply, 110 or 220 V +/- 10%