BergEng.com Logo
Search items in our store
BergEng.com Logo
Search items in our store
ilac-MRA ANAB Accredited Calibration Laboratory

Echo Ultrasonics SoniX UT Ambient Temperature NDT Ultrasonic Couplant

SKU: SONIX
$88.80

Purchase Echo Ultrasonics SoniX UT Ambient Temperature NDT Ultrasonic Couplant

Echo Ultrasonics SoniX UT Ambient Temperature NDT Ultrasonic Couplant

SKU: SONIX

$88.80
This product has been discontinued.
 
Description
SoniX™ UT is a universal ambient temperature ultrasonic couplant which provides a strong, lubricating, water-soluble coupling film. SoniX has a slow drying time making ideal for extended inspection times.

SoniX has a broad operating temperature range of 18°F to 120°F (-8°C to 50°C) making it ideal for most flaw detection and thickness gaging applications. It is also environmentally and operator friendly with no formaldehydes, nitrates or nitrites.
Additional Info
Package Includes
Specifications
Specifications:
  • Med. Viscosity: 40,000 cps LVT Spindle 4 @ 6 rpm
  • pH: 8 nominal at 20°C.
  • Operating Temperature: 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gaging applications.
  • Halogens and Sulfur: less than 50 ppm.
ASTM F519, conforms: ASTM F519 describes mechanical test methods and defines acceptance criteria for exposure to chemicals encountered in Service Environments, such as fluids, cleaning treatments or maintenance chemicals including ultrasonic couplants that come in contact with the plated/coated or bare surface of the steel.
 
This test method provides a means by which to detect possible hydrogen embrittlement of steel parts (plated/coated or bare) due to contact with chemicals during manufacturing, overhaul and service life.
 
Removal: Wash with water or wipe with paper or cloth rag before couplant dries. If couplant has dried, pressure wash or use brush and running water.
Features
  • Strong ultrasonic coupling film strength. 
  • Slow drying for extended inspection time.
  • Adheres well to vertical and overhead surfaces without resorting to gel-like viscosity (which often snowplows).
  • Superior transducer lubricant that will extend transducer life in flaw detection applications.
  • Reduced surface tension; provides fast wetting.
  • Broad operating temperature range: 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gaging applications.
  • Good ferrous corrosion inhibition; compatible with most metals, plastics and composites.
  • Completely salt stable; will not thin with corrosion, marine environment or highway infrastructure subjected to de-icing salts.
  • Safety: no formaldehyde; environmentally benign.
  • Environment and operator friendly – no formaldehydes, nitrates or nitrites.

Product details

Tech support available

Product codes
SX1, SX5, SX-7, SX-55
Product weight
11.00

Government buyers

Berg Engineering & Sales Co., Inc. makes purchasing for Government Buyers simple.

Berg Engineering & Sales Co., Inc. will gladly accept Government Purchase Cards with the VISA, MasterCard or American Express logo. We accept regular MasterCard, Visa, American Express credit cards also.
Berg Engineering offers Net 30 Terms to most Federal, State and Local government agencies.

Berg Engineering CAGE Code: 68062

Small business

Berg Engineering & Sales Co., Inc. is a Small Business as determined by the SBA's Small Business Size Standards.

Ready to request a quote or purchase

Go to our home page at https://www.BergEng.com to begin your search, or contact us to submit an RFQ or purchase order.
Phone: 1-847-577-3980 (M-F, 8:00 – 4:30pm CT)
Fax: 847-577-0474
Email: [email protected]