    SoniX™ UT is a universal ambient temperature ultrasonic couplant which provides a strong, lubricating, water-soluble coupling film. SoniX has a slow drying time making ideal for extended inspection times.

    SoniX has a broad operating temperature range of 18°F to 120°F (-8°C to 50°C) making it ideal for most flaw detection and thickness gaging applications. It is also environmentally and operator friendly with no formaldehydes, nitrates or nitrites.

    Features

    • Strong ultrasonic coupling film strength. 
    • Slow drying for extended inspection time.
    • Adheres well to vertical and overhead surfaces without resorting to gel-like viscosity (which often snowplows).
    • Superior transducer lubricant that will extend transducer life in flaw detection applications.
    • Reduced surface tension; provides fast wetting.
    • Broad operating temperature range: 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gaging applications.
    • Good ferrous corrosion inhibition; compatible with most metals, plastics and composites.
    • Completely salt stable; will not thin with corrosion, marine environment or highway infrastructure subjected to de-icing salts.
    • Safety: no formaldehyde; environmentally benign.
    • Environment and operator friendly – no formaldehydes, nitrates or nitrites.

    Specs

    Specifications:
    • Med. Viscosity: 40,000 cps LVT Spindle 4 @ 6 rpm
    • pH: 8 nominal at 20°C.
    • Operating Temperature: 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gaging applications.
    • Halogens and Sulfur: less than 50 ppm.
    ASTM F519, conforms: ASTM F519 describes mechanical test methods and defines acceptance criteria for exposure to chemicals encountered in Service Environments, such as fluids, cleaning treatments or maintenance chemicals including ultrasonic couplants that come in contact with the plated/coated or bare surface of the steel.
     
    This test method provides a means by which to detect possible hydrogen embrittlement of steel parts (plated/coated or bare) due to contact with chemicals during manufacturing, overhaul and service life.
     
    Removal: Wash with water or wipe with paper or cloth rag before couplant dries. If couplant has dried, pressure wash or use brush and running water.

    RECENTLY VIEWED PRODUCTS

    carousel button
    • FlawTech Standard Radiographic Kit
    • PHB-3000E Electric Portable Brinell Hardness Tester
    • Synergys ASHOOTER Plus Laser Shaft Alignment System
    • PH Tool 90 Degree Curved 5-Step Block
    • Echomac® VM Velocity Measurer - Nodularity
    • Dakota RX8-DL Racing Thickness Gauge
    • Exacto Pit Depth Gauge Digital Kit
    • CorDEX LaserMETER 3000XP
    • Waygate Krautkramer USLT 2000DP3
    • Waygate Krautkramer Spot Face Low Frequency Eddy Current Probes, Differential Reflection
    • GAL Gap Wedge Gauges
    • MagnaFlux Daraclean 282 Aerospace Alkaline Cleaner
    • Sensor Networks Hi-Def PTZx
    • PH Tool Navy Eddy Current Standard, Special Alloy
    • UTMP-5 Ultrasonic Thickness Gauge
    • GAL Electronic Caliper, 6 Inch
    • Envirosight Rovver X
    • Berg Rental - Fluke FLK-TiR110 9HZ Thermal Imager
    • PH Tool Pacs Notch Blocks
    • Zetec Zircon Portable High Performance Phased Array UT Instrument
    • Tramex Skipper 5 Marine Moisture Meter
    • Sherwin CP-1 White Contrast Paint Stripable Aerosol Case
    • Pocket Digital Pit Gauge
    • Waygate Krautkramer H.M Immersion Transducers
    • Mitutoyo 293 Series Digimatic Micrometer
    • Technisonic 5MHz, High Res, 3/16” element Transducer
    • Chemetall Ardrox 9PR50 Solvent-Based Penetrant Remover
    • Mitutoyo 326 Series Screwthread Micro Inter
    • Mitutoyo MDE Quantumike Micrometer
    • Mitutoyo QM Height Series High Performance Height Gage
    • Berg Flaw Adapter, Dual Lemo 00 Double Plug to Dual BNC Male
    • Sherwin CP-2 White Contrast Paint Non-Stripable Aerosol Case
    • DeFelsko PosiTest HHD Electrode Rod Thumb Screws
    • Sony XC-505 Video Camera
    • Waygate Technologies Midori ULB-35 UV Fiber-Optic LED Light Source
    • PH Tool ERVD (“Extended Range Variable Diameter”) Thickness Calibration Block
    • Berg Rental - USN 60 Ultrasonic Flaw Detector
    • Waygate Krautkramer  Eddy Current Conductivity Reference Blocks
    • 3rd Generation PHB-300 Automatic Magnetic (Brinell) Hardness Tester
    • Extech Multiview Digital Multimeter
    • Zetec MIZ-85iD Eddy Current Instrument
    • Dakota MVX Dual Element Corrosion Thickness Gauge
    • CorDEX ToughPIX 2304XP - 8GB Card
    • DeFelsko PosiTector DPM Dew Point Meter Probes
    • Parker TB10-SP Special Weight Lift/Defect Test Bar
    • .060" Delay tip Sonopen Type Pencil Transducer 1/4-36 thread
    • Echo Spot Weld Ambient temperature UT couplant for spot weld inspections
    • Berg 1/16 Carbide Ball Indentor Class B
    • Magnaflux SF-Series Demagnetizers Free-Standing, Continuous Duty Demagnetizers
    • Wilson Turntable Vise
    • GE Exosen 30, 8 oz. Bottle
    • Spectroline ML-3500S Spot
    • Dakota PZX-ZDL Dual Element Corrosion Thickness Gauge
    • MagnaFlux Zyglo ZA-1633 Method B, Post Emulsified Lipophilic FPI System
    • Eishin NiCr Type 1 Test Panels
    • Tramex EIFS Inspection Kit
    • PH Tool ASTM E317 Resolution Block, Fig. 6, #3 Fbhs Inch -7075-T6  Aluminum
    • DeFelsko Legacy Burnishing Tool
    • Waygate Krautkramer VS Angle Beam Transducers Dual Element Style - European Standards
    • GAL Hi-Lo Welding Gauge
    • FlawTech Lap Joint
    • Waygate Krautkramer IPS Style Immersion Transducers
    • Mitutoyo Connecting cable (SJ301)
    • IBG Crack detection probe with X-coil, 100kHz to 800kHz
    • Waygate Krautkramer Spare Soles WPE for WB and WK Transducers Set of 10
    • Berg Rental - CL5 Ultrasonic Thickness Gauge
    • Danatronics Coiled Cable, 4'
    • Dakota PMX4-DL High Penetration Thickness Gauge
    • PH Tool ERVW Pipe Calibration Blocks, Circ Scan
    • Berg 1/16 Carbide Ball Penetrator Class B
    • PH Tool MIL-STD-271F Performance Verification Reference Block, 6061-T6 Aluminum
    • Waygate Krautkramer Integral Wedge Phased Array Probes
    • Waygate Krautkramer VRY Angle Beam Transducers Dual Element Style - European Standards
    • Sherwin TWIN KDS Panels
    • Wilson Carbide ball indenter 5mm for RH2150
    • Luxxor Liquid Light Guide
    • Berg 3C2-234 QQI Test Shims
    • AFFRI TESTING INSTRUMENTS Universal Hardness Tester LD3000AX
    carousel Button