GE USD 15SX Krautkramer (082-034-229)

    GE USD 15SX Krautkramer
     

     

    DISCONTINUED

    This product has been discontinued.


    • Product Code.:
      082-034-229
    • Original Code:
      082-034-229
    • Tech Support Available
    • Product Weight: 34.00

    HAVE A QUESTION?
       Hours:   8:00 am to 4:30 pm CST

    Description

    The USD 15SX Large screen portable flaw detector is a single channel systems level ultrasonic instrument available in several configurations to meet specific testing needs

    Applications:

    • General immersion flaw and thickness testing
    • Forging inspection
    • Billet inspection
    • Composite inspection
    • Roll testing

    Base Instrument Package:

    • Operating manual
    • Power cord
    • Certificate of Conformity 

    Recommended Accessories:

    • UD160 NiCAD battery pack (can be internally charged)
    • UD19-1 Printer cable (Epson) adapter required
    • DB-9/25 DB9 to DB25 serial adapter
    • USD15S-CB Fabric carry bag
    • UD20 Computer cable 25 to 9 pin
    • UDFW UltraDoc utility software
    • ROC450 Recorder output cable (gates "A" and "B")
    • OP-15 Operation manual
    • SM-15 Service manual
    • I/O-37 Interface cable (unterminated at one end)

    Optional Accessories:

    • UD150 Battery charger (external) requires UD153
    • UD153 Battery holder
    • NBD Batteries "D" size NiCAD’s (12) (cannot be charged internally, external only)

    Specifications:
    Range
    From .22 inch (5.6mm) to 390 inches (9906mm) in steel (Long.)
    (2.5 to 9.999") (63.5 to 254mm) continuously variable or in pre-selected steps
    Display Start
    -1 inch (-25.4mm) to 200 inches (5080mm) in steel (long.)
    Velocity
    Continuously adjustable from 0.04 to 0.5 inches/microsecond. (1.02 to 12.7mm/microsecond.) Two programmable fixed velocities
    Probe Delay
    0 to 999.99 microseconds
    Gain
    From 0 to 110 dB in steps of 0.5 dB. Gain steps selectable between 0.5 / 1.0 / 2.0 / 6.0 ; programmable from 6.5 dB to 24 dB in 0.5 dB steps
    Test Modes
    Pulse echo and dual
    Pulsar
    Spike-pulse, pulsar max. 480V. Rise time <30 ns. Charging capacitor is switchable between220, 1000, and 2000 pF
    Damping
    33, 50, 75, and 500 Ohms.
    Pulse Repetition Frequency
    1 to 1200 Hz (12KHz). Automatically coupled to the display and gate settings or freely adjustable in 50 Hz steps
    Amplifier Bandwidth
    Narrow band filters: 0.5, 1, 2, 2.5, 4, 5, 10, 15MHz, broad band 0.3 - 20 MHz (-3dB)
    Reject
    Linear reject 0% to 80% FSH
    Vertical Linearity
    +/- 2%
    Distance Amp Correction (DAC)
    Recordable up to 20 reference echoes, 40 dB dynamic range, maximum slope 6 dB/microsecond. TCG, CGB (curve with gate A)
    Display
    Bright, high contrast electroluminescent screen, 7.68 x 3.82 ins., 512 x 256 pixels (195 x 97 mm)
    Units of Measurement
    Inch or mm
    Gates
    3 independent gates (one can be used as an interface start gate) are adjustable in the complete display range. Bar presentation
    Thickness Resolution
    Readings to 0.001 inch (precision to 0.0005 inch)
    Readings to 0.025 mm (precision to 0.0127 mm)
    Interface Echo Start
    Applicable to display, or flaw gate start
    Display of Gate Readings
    Sound path, projected distance, depth, signal amplitude in percent screen height or as a dB difference to a gate threshold or to a stored reference echo
    A-Scan Functions
    Display options include: signal freeze, peak hold, and display average of the last 2 - 16 frames in the rectified mode
    A-Scan/ Data Memory
    Up to 100 A-scans can be stored internally, along with complete instrument settings, including DAC
    Dialog Languages
    Selectable: English, French, German, Italian, Portuguese, and Spanish
    Test Report Printout
    Test reports including instrument parameters, A-scans, and DAC
    Interfaces and Outputs
    RS 232C for bi-directional communications. 37 pin interface with alarm outputs and analog outputs, (time of flight or amplitude) for each gate in real time at full PRF.
    Sync. input, sync. output, alarm reset, test data release
    AC Operation
    Direct operation from mains input, 90V to 264V, auto selection
    Battery Operation
    Primary operation is a battery pack - can be internally or externally charged.
    Optional operation 12 alkaline or NiCAD "D" size external charging only.
    Battery Charger
    Built-in power / charger unit. Charging time 5 hours. Remote external charging available (option)
    Operating Temperature
    0 degrees to 130 degrees F
    -18 degrees to 54 degrees C
    Storage Temperature
    -20 degrees to 150 degrees F
    -29 degrees to 66 degrees C
    Size (H x W x D) and Weight
    7.56" x 14.41" x 13.5". Weight 19 lbs. without batteries, 22 lbs. with batteries.
     

     

    Features

    • Extra Large EL Display (7.7" x 3.8") (196 x 97mm)
    • 3 Independent Monitor Gates
    • 150 Dataset Memory Locations
    • Selectable PRF to 12 KHz.
    • 40dB DAC/TCG
    • Trigonometric Flaw Location
    • Alphanumeric Dataset Naming
    • A-Scan Compare Function
    • RF Display Mode With RF Output
    • Video Output
    • 8 Frequency Selections Including Broadband
    • 150 data set memory, including A-scan storage
    • 8 frequency selections
    • 3 bar display monitor gates
    • Interface echo gate start
    • 40 dB dynamic range distance amplitude correction, curved gate bar, and time corrected gain
    • Digital distance and amplitude measurements to all gates
    • Trigonometric flaw location
    • Analog output 0 - 5 V (with selectable DC offset)proportioned to distance and amplitude (selectable in each gate)
    • Selectable pulse repetition frequency to 12 KHz(controlled in 50 Hz increments)
    • Inch and mm control units
    • Selectable pulsar power
    • Damping selectable in discrete steps
    • RF display plus positive and negative half waves and full wave selectable
    • High resolution 512 x 256 pixel electroluminescent display
    • RS232 bi-directional printer / computer interface to 19200 baud
    • Auto recognition 90V to 220V 50/60 cycle AC operation
    • Integral charger for charging UD160 battery pack only (not for D-cell NiCAD's)
    • Master Slave operation
    • Externally clockable
    • Single 37 pin output connector for all gate & timing signals (custom output connection cables available)
    • Composite video output (50 Hz PAL)
    • Oscilloscope compatible RF output
    • High speed data PC link (requires optional computer card)

    Specs

    RangeFrom .22" (5.6mm) to 390" (9906mm) in steel (Long.)
    (2.5in to 9.999in) (63.5 to 254mm) continuously variable or in pre-selected steps
    Display Start-1 inch (-25.4mm) to 200 inches (5080mm) in steel (long.)
    VelocityContinuously adjustable from 0.04 to 0.5 inches/microsecond. (1.02 to 12.7mm/microsecond.) Two programmable fixed velocities
    Probe Delay0 to 999.99 microseconds
    GainFrom 0 to 110 dB in steps of 0.5 dB. Gain steps selectable between 0.5 / 1.0 / 2.0 / 6.0 ; programmable from 6.5 dB to 24 dB in 0.5 dB steps
    Test ModesPulse echo and dual
    PulsarSpike-pulse, pulsar max. 480V. Rise time <30 ns. Charging capacitor is switchable between220, 1000, and 2000 pF
    Damping33, 50, 75, and 500 Ohms
    Pulse Repetition Frequency1 to 1200 Hz (12KHz). Automatically coupled to the display and gate settings or freely adjustable in 50 Hz steps
    Amplifier BandwidthNarrow band filters: 0.5, 1, 2, 2.5, 4, 5, 10, 15MHz, broad band 0.3 - 20 MHz (-3dB)
    RejectLinear reject 0% to 80% FSH
    Vertical Linearity+/- 2%
    Distance Amp Correction (DAC)Recordable up to 20 reference echoes, 40 dB dynamic range, maximum slope 6 dB/microsecond. TCG, CGB (curve with gate A)
    DisplayBright, high contrast electroluminescent screen, 7.68 x 3.82 ins., 512 x 256 pixels (195 x 97 mm)
    Units of MeasurementInch or mm
    Gates3 independent gates (one can be used as an interface start gate) are adjustable in the complete display range. Bar presentation
    Thickness Resolution Readings to 0.001 inch (precision to 0.0005 inch)
    Readings to 0.025 mm (precision to 0.0127 mm)
    Interface Echo StartApplicable to display, or flaw gate start
    Display of Gate Readings Sound path, projected distance, depth, signal amplitude in percent screen height or as a dB difference to a gate threshold or to a stored reference echo
    A-Scan Functions Display options include: signal freeze, peak hold, and display average of the last 2 - 16 frames in the rectified mode
    A-Scan/Data MemoryUp to 100 A-scans can be stored internally, along with complete instrument settings, including DAC
    LanguagesEnglish, French, German, Italian, Portuguese, and Spanish
    Test Report Printout Test reports including instrument parameters, A-scans, and DAC
    Interfaces and OutputsRS 232C for bi-directional communications. 37 pin interface with alarm outputs and analog outputs,(time of flight or amplitude) for each gate in real time at full PRF.
    Sync. input, sync. output, alarm reset, test data release
    AC OperationDirect operation from mains input, 90V to 264V, auto selection
    Battery OperationPrimary operation is a battery pack - can be internally or externally charged.
    Optional operation 12 alkaline or NiCAD "D" size external charging only.
    Battery ChargerBuilt-in power / charger unit. Charging time 5 hours. Remote external charging available (option)
    Operating Temperature 0 degrees to 130 degrees F
    -18 degrees to 54 degrees C
    Storage Temperature -20 degrees to 150 degrees F
    -29 degrees to 66 degrees C
    Size (H x W x D) and Weight 7.56" x 14.41" x 13.5". Weight 19 lbs. without batteries, 22 lbs. with batteries.

    Additional Info

    • PDF Brochure