Mitutoyo SJ-301 Portable Surface Roughness Tester
|
Code: 178-954-4A
Discounted Price: $3,722.40 List Price: Shipping Weight: 5.00 pounds IN STOCK |
|
![]()
Portable surface roughness tester with a touch-panel LCD and a built-in printer
Features
- Graphic display of measured profile
- Easy-to-operate touch-panel
- Built-in printer and battery operation
- JIS/DIN/ISO/ANSI compatible 25 evaluation parameters and 3 analysis graphs
- 300μm wide measuring range detector
- Statistical processing function included
- Compatible with PC based Surfpak-SJ software
- Dual power supply (AC adapter/Rechargeable battery)
- Auto-sleep function for power conversion
Conforming to various standards
- Conforming to the JIS (1994-1998), ISO, DIN, and ANSI standards.
- Additionally, the horizontal roughness parameters S, Sm, tp (mr) can be reported. The SJ-301 also performs such special parameters as plateau rate and RK-related parameters.
Storing measurement conditions and data
- The SJ-301 main unit can store a maximum of 5 sets of measuring conditions. Individual measuring conditions can be selected for each workpiece.
- The measuring conditions stored in the SJ-301 can be recalled and switched by direct key operations.
- Measured data can be saved at the measurement site & be printed out or recalculated later.
- By using an optional memory card, a maximum of 20 sets of measuring conditions, measured data, and statistical results can be stored.
Key-masking function
- This function limits touch panel operation to prevent the detector calibration data and measuring conditions from being altered or deleted.
- Measuring conditions can be easily controlled among multiple users. Resistance to environment
- The SJ-301 keypads have excellent durability — No need to worry about oil stains from the user’s hands.
Reading profiles in the LCD window
- Measurement results and analysis profiles can be read in the LCD window.
- Signal waves can be scrolled smaller or larger, enabling the operator to read fine details.
High-speed thermal printer
- Equipped with a highly sophisticated, high-speed thermal printer.
- Selectable orientation for printout — Choose the portrait for conventional printout or the landscape for printing out the image as it is displayed.
- BAC (Bearing Area Curved ADC (Amplitude Distribution Curve) can be printed out.
Statistical analysis functions
- Statistical analysis of one parameter is possible.
- Displays and prints frequency histograms as well as statistical calculation results (average, standard deviation, maximum value, minimum value, pass ratio).
Auto calibration
- Calibration can be easily performed by simply inputting and measuring the Ra value inscribed on the roughness reference specimen.
- No adjustment with a tool, such as a volume adjustment, etc. is required. GO/NG judgment function
- Tolerance values in three-steps can be set for the surface roughness parameters
- Judgment symbol is displayed in the result display for a quick judgment of GO/NG.
Customization function
- The user can select only the parameters needed from a variety of surface roughness parameters provided.
Mobility
- A built-in battery in the SJ-301 makes it possible to inspect surface roughness even at a site where there is no electrical outlet available.
- Portable and convenient — the drive unit and the detector can be stored in the display unit. (Carrying case is a standard accessory.)
- Measurement can be performed while the display unit is in the carrying case. The carrying case can be used to protect the display unit.
Arbitrary evaluation length
- An arbitrary evaluation length within the range of 0.3 mm - 12.5 mm (Unit: 0.1 mm)
- can be set.
- Measurement in a limited space, where measurement is difficult under the measuring conditions in accordance with JIS standards, is made possible by using the start-up OFF function.
One-step detector replacement
- Special detectors are available for measurements that cannot be performed with a standard detector - such as measurement of small-diameters and deep-grooves.
- No tool is required for replacing the detector. Simply pull out and insert a detector.
- Just one SJ-301 can perform measurement on a variety of workpiece's, since various types of detectors, depending on the workpiece, can be used.
High-accuracy detector
- SJ-301 employs a differential inductance method, which is used in high-end models.
- Measurement with a high-accuracy and a wide measuring range of 300μm.
- Parameters that require high-accuracy feed such as SM and S can be measured with the SJ-301.
- The detector can be retracted into the drive unit when the SJ-301 is not performing a measurement.
Selectable language for display/ printout
- Display/ printout language is selectable from among English, German, French, Italian and Japanese.
| Technical Data | ||
| Measuring Range: | Z-axis: 300μm (12000μin) X-axis: 12.5mm (.5”) |
|
| Display Unit | ||
| Assessed Profile: | Primary profile (P), Roughness profile (R), DIN4776, MOTIF | |
| Evaluation Parameter: | Ra, Ry, Rz, Rt, Rp, Rq, Rv, Sm, S. Pc, R3z, mr, Rpk, Rvk, oc, Rk, Mr1, Mr2, Lo, Ppi, R, AR, Rx, A1, A2 |
|
| Analysis Graph: | BAC1, BAC2, ADC | |
| Roughness Standard: | JIS, DIN, ISO, ANSI | |
| Sampling Length (L): | .01”, .03”, .1”, .3” (0.25mm, 0.8mm, 2.5mm, 8mm) | |
| Cut-Off Length: | λc: .01”, .03”, .1”, .3” (0.25mm, 0.8mm, 2.5mm, 8mm) λs: .10”, .32”, 1” (2.5mm, 8mm, 25mm) |
|
| Number of Sample: | x1, x3, x5, xL [.01” - .49” (0.3mm - 12.5mm)] | |
| Digital Filter: | 2CR-75%, 2CR-75% (phase corrected), Gaussian-50% | |
| Resolution/Range: | 12.8μin/12000μin (0.32μm/300μm), 3.2 μ in/3000μin (0.08μm/75μm), 1.6 μ in/1500μin (0.04μm/37.5μm), .4 μ in/375μin (0.01μm/9.4μm). |
|
| Displaying Range: | Ra, Rq: .4μin - 3000μìin (0.01μm - 75μm) Ry , Rz, Rt, Rp, Rv, R3z, Rk, Rpk, Rvk, R, AR, Rx: .8 μ in - 12000μin (0.02μm - 300μm) S, Sm: 79 μ in - 160000ìin (2ìm - 4000ìm) PC: 6.35/inch - 12700/inch (2.5/cm - 5000/cm) σc: -300μm - 300μm Lo: .004inch - 8inch (0.1mm - 200mm) mr , Mr1, Mr2: 0 - 100% A1, A2: 0 - 15000 |
|
| Recording Magnification: | Vertical: 50x, 100x, 200x, 500x, 1000x, 2000x, 5000x, 10000x, 20000x, 50000x, 100000x AUTO Horizontal: 1x, 2x, 5x, 10x, 20x, 50x, 100x, 200x, 500x, 1000x, AUTO |
|
| Printer: | Thermal printer [printing width: 1.89” (48mm)] | |
| Statistical Processing (for each parameter): | Maximum value, Minimum value, Mean value, Standard deviation (σ), Pass ratio, Frequency distribution table | |
| Tolerance Judgment: | Upper and lower limit values for three parameters can be specified. | |
| Measuring Condition Storage: | 5 sets of measuring conditions | |
| Auto-Sleep (turning off): | After five minutes without operation | |
| Calibration: | Automatic calibration entering the value of roughness specimen. | |
| Power Supply: | Via AC adapter (DC7.5V, 1.5W) / built-in rechargeable battery. | |
| Rechargeable Battery: | Charging time: 15 hrs. (for 1000 measurements without printing) | |
| Data Output: | RS-232C input/output, SPC output | |
| Mass: | Approximately 2.64 lbs. (1200g) | |
| Drive Unit | ||
| Drive speed | Measuring: | 0.25mm/s (0.1”/s), 0.5mm/s (.02”/s) |
| Returning: | 1mm/s (.04”/s) | |
| Connecting Cable Length: | 1m (39”) | |
| Mass: | 42 lbs. (190g) | |
| Standard Detective | ||
| Detecting Method: | Differential inductance | |
| Measuring Range: | 300μm (912000ìin) | |
| Material of Stylus: | Diamond | |
| Stylus Tip Radius: | 5μìm (200μin) | |
| Radius of Skid Curvature: | 40mm (1.57”) | |
| Measuring Force: | 4mN (0.4gf) | |
| Mass: | .04 lbs. (18g) | |
| Code | Name | Price | Qty |