DMS Go Ultrasonic Thickness Gauge with A-Scan and Data Recorder
|
Code: 022-510-176
***NEW PRODUCT*** |
|

The DMS Go from GE’s Inspection Technologies business is a high-end thickness gauge which combines an innovative, easy-to-use user interface, powerful data management and an ability to provide accurate, reliable and comprehensive thickness inspection data. It is ideally suited for a wide range of applications including measuring for corrosion in the oil and gas sector and in power generation.
The DMS Go uses the same operating platform as the USM Go portable flaw detector. By means of a simple software purchase your DMS Go can benefit from all the USM Go functionalities and perform advanced flaw detections
|
DMS Go Series/Upgradeability The DMS Go can be upgraded to include numerous features/functions. Features/functions can also be added at a later time. See DMS Go Series chart below.
TOPCOAT Technology Supported
With the patented “TopCOAT“ method we have been able to optimize the corrosion measurement through paint coatings: this method makes it possible to measure materials showing heavy corrosion on backwall surfaces, and even the slightest pitting can be detected thanks to a high gain. The paint coating and base metal are measured in one measurement process, and displayed simultaneously. Auto-V Supported If your components are uncoated, you have the Auto-V feature at your disposal. It is a clearly simplified version of the conventional thickness measurement and, as such, a unique method. Auto-V even allows you to measure the thickness of components with unknown material velocity. This enables you to measure different uncoated materials without any additional calibration – and without any calibration standards. It’s not necessary to know the material velocity to be able to measure – this previous disadvantage no longer exists. Robust Construction
Ergonomics The DMS Go ultrasonic thickness gauge has been ergonomically designed to provide an instrument which is light, small and easy to use in the harshest inspection environments.
Virtual Demo |
High Performance Thickness Measurement
High Capacity Data Recorder and Compatibility with Powerful Data Management Systems The DMS Go offers powerful data recording and data management capability to meet the most demanding of thickness gauging and corrosion inspections. Important features include:
Intelligent Storing and Managing The DMS 2’s on-board Data Recorder makes all the options for up-to-date documentation and modern data management available to you:
Connectivity
A standard USB connection to allow data to be downloaded from the flaw detector for further analysis or storage. The instrument is standard delivered with a 2 GB SD memory card (can accommodate up to 16GB card size). Reports are produced in jpeg or bmp format so there is no need for special reading software. A simple on-board data logger to collect and save thickness measurements. |
Display
|
Type |
WVGA Color LCD with adjustable LED Backlight |
|
Active Area |
W: 108 mm (4.25") |
|
Screen Diagonal |
5.0" |
|
Pixel Resolution |
W x H: 800 x 480 pixels |
Environment
|
Languages |
English, German, French, Spanish, Chinese and Japanese |
|
Size |
175 mm x 111 mm x 50 mm (6.8” x 4.3” x 1.9”) |
|
Weight |
870 g (1.9 lb) with the battery |
|
Temperature Shock (Storage) |
3 cycles: 4 hrs at –20°C (-4°F) up to 60°C (140°F), 4 hrs at 60°C (140°F), |
|
Vibration |
MIL-STD-810E method 514.5, Procedure I, Annex C, Figure 6, General Exposure: 1 hr each Axis |
|
Shock |
6 cycles each Axis, 15 g, 11 ms Half Sine, MIL-STD-810E Method 516.5, Procedure I |
|
Loose Cargo (In Shipping Container) |
MIL-STD-810E Method 514.5, Procedure II |
|
Transit Drop (Packaged for Shipment) |
MIL-STD-810E Method 516.5, Procedure IV, 26 drops |
|
Operating Temperature Range |
0°C to 55°C (32 to 131°F) |
|
Storage Temperature Range |
-20°C to 60°C (-4 to 140 °F) with battery, 24 hrs |
|
Dustproof / Waterproof |
As per IEC 529 Specification for IP67 Classification |
|
Hazardous Atmosphere |
As defined by MIL-STD-810E, Method 511.3, Procedure 1 |
Compliance
|
EMC/EMI |
EN 55011 & EN61000-6-2:2001 |
|
Ultrasound |
EN 15317, EN12668 , ASTM-E1324, ASTM-E317 |
I/O Connectors
|
Transducer |
Dual lemo-00 (Coax) |
|
Mini USB |
|
|
Power IN and TTL Alarm OUT |
|
Power Supply
|
Battery Type |
Li-ion battery |
|
Operating Time |
Min 8 hours in typical DMS Go continuous operation |
|
On Board Charging |
|
|
Off Board Charging with Optional Adaptor |
|
|
Proportional Battery Gauge Indicating Remaining Operation Time |
|
|
Charger |
.“Universal” AC (100-240 V, 50-60 Hz) meets CCC, CE, UL, |
Unit
|
Measuring Range |
0.40 mm to 650 mm (0.010‘‘ to 25.00‘‘) in steel, in standard operation, depending on |
|
Digital Display Resolution |
0.01 mm or 0.1 mm (0.001” or 0.01”) selectable over the entire measuring range |
|
Material Velocity Range |
250 to 16,000 m/s (0.0098” to 0.6299”/μs) |
|
Units |
mm or inch |
|
Measurement Techniques |
All measurments using Zero Crossing technique single element IP to 1st echo / single element multi echo / dual-element IP to 1st echo / dual element multi echo |
|
Measurement Techniques (DMS Go TC only) |
TopCoat (Patent# 6,035,717) and Auto-V |
|
Measurement Display Modes |
Temperature Corrected Thickness |
|
Thickness and large A-Scan |
|
|
B-Scan |
|
|
MIN / MAX Capture |
|
|
Differential |
|
|
Calibration |
One-point, Two-point |
|
Auto or Manual On-block and Off-block Zero |
|
|
Automatic V-path Correction |
|
|
Update Rate |
32 Hz in MIN/MAX-capture Mode and B-Scan Display Mode |
|
4 Hz or 8 Hz or 16 Hz (Selectable) in Standard Mode |
|
|
Receiver |
110 dB Dynamic Range |
|
Automatic ain control with manual (set by user) |
|
|
High, low and Auto Gain Limit |
|
|
Pulser |
Square Wave, Pulse-width and -voltage (120 V or 250 V) automatically matched to probe |
|
Memory |
2 GB SD Card included. Up to 16 GB memory cards can be used |
|
Data export as PDF, XML, CSV, DAT. Jpeg screen copy |
|
|
Data Recorder |
100,000 readings per file. Multiple files can be stored on SD card up to card capacity |
|
File Formats |
6 File Formats with DR Option (3 with Base Instrument) |
|
Attachments |
Insertion of 2x2 to 9x9 MicroGrid per Measuring Point |
|
1 to 16 user-definable comments for each file format with up to 16 alphanumeric characters per measuring point |
|
|
A-Scan |
|
|
B-Scan |
Software
|
UltraMATE Lite |
Simple data management program for transferring measurement data files to a PC, including integration of the data into Windows programs |
|
UltraMATE |
Extensive data management program for displaying and printing measurement data as graphics, for managing test data, for entering comments on files |
|
Software Development Kit |
Available for integration into other software applications |